Environ

Electrical Injury

search

Electrical Injury, Electrical Burn, High Voltage Electricity, Electricity Shock, High Voltage Injury, Low Voltage Injury

  • Epidemiology
  1. Electrical injuries cause 1000 deaths in U.S. per year
  • Pathophysiology
  1. Electricity travels a path until meets resistance
    1. Carbonized tissue resists continued current
  2. Electrical Injury results in thermal Burn Injury
  3. Most common injury sites
    1. Deep Skin injury
    2. Neurologic injury
      1. Spinal cord injury (e.g. motor or sensory deficit)
      2. CNS injury (e.g. Altered Level of Consciousness)
    3. Eye Injury
      1. Cataracts
      2. Corneal burn
      3. Retinal Detachment
    4. Cardiovascular injury
      1. Cardiac Arrest
      2. Arrhythmia
  • Types
  1. Alternating Current (AC): Low voltage home injury
    1. AC is 3 times more dangerous than DC at same voltage
    2. May result in muscle Tetany
      1. Patient involuntarily holds source
      2. Prolongs duration of contact and increases injury
  2. Direct Current (DC): High voltage Occupational Injury
    1. May throw patient from jolt of energy
    2. May result in blunt injury in addition to burns
  3. Voltage
    1. Low voltage Electrical Injury: <1000 Volts
      1. House power outlet: 110 to 240 volts
    2. High voltage Electrical Injury: >1000 Volts
      1. Power Lines: 7200 volts
      2. High voltage power lines: 155,000 to 765,000 volts
    3. Lightning Injury: 30 million to 1 billion volts
  4. Arc Injury
    1. Patient part of arc of current between 2 objects
    2. Most serious Electrical Injury
      1. Severe blunt Trauma may result
      2. Temperature may exceed 2500 C (4532 F)
  • Risk Factors
  • Lethal Electrical Injury
  1. Wet skin exposure
  2. Tetany
  3. Transthoracic electrical pathway (Arm-to-arm transmission, Arm to leg transmission, Chest direct contact)
    1. Does not increase risk of delayed arrhythmia if alive at Emergency Department presentation
    2. Bailey (2007) Emerg Med J 24(5):348-52 [PubMed]
  • History
  1. Type of electrical exposure (e.g. house power outlet, battery or power line)
    1. Attempt to estimate voltage (see above)
  2. Direct current or alternating current
  3. Duration of electrical current exposure (e.g. may occur with Tetany)
  4. Modifying factors (e.g. wet skin that increases electrical conductivity)
  5. High risk distribution of injuries (trans-thoracic contact points to electrical source)
    1. Arm-to-arm transmission
    2. Arm to leg transmission
    3. Chest direct contact
  6. Secondary Traumatic injuries (e.g. patient thrown)
  7. Arrhythmias noted on prehospital evaluation
  • Exam
  1. See Trauma Primary Survey
  2. See Trauma Secondary Survey
  3. Estimate the percentage of total body surface area burn
    1. Precaution: Deep tissue damage may be extensive despite minimal surface skin changes
  4. Evaluate and monitor extremities with Electrical Injury for Compartment Syndrome
    1. Diminished pulse
    2. Increased pain on passive extremity movement
    3. Pallor
    4. Increased compartment pressures
  • Labs
  1. First-line labs
    1. Complete Blood Count (CBC)
    2. Basic metabolic panel (Chem8)
    3. Creatine Kinase (CK)
    4. Urinalysis
  2. Labs with lower efficacy in Electrical Burns
    1. Cardiac Enzymes (Troponin, CK-MB)
      1. Poor correlation with cardiac damage and LV dysfunction in Electrical Burns
      2. CK-MB is falsely increased in Electrical Burns
  • Diagnostics
  1. Electrocardiogram
    1. Evaluate for arrhythmia
  • Management
  • General
  1. Resuscitation and Stabilization should follow ACLS and Trauma protocols
    1. See ABC Management
    2. See Trauma Evaluation
  2. Electrical (Thousands of volts) and lightning (Millions of volts) injuries are treated differently
    1. See Lightning Injury
  3. Specific Electrical Burn management
    1. See Burn Management
    2. Parkland formula for fluid Resuscitation typically underestimates requirements in Electrical Burns
    3. Rhabdomyolysis management if elevated CK
      1. Maintain Urine Output 200-300 ml/hour
    4. Evaluate for Compartment Syndrome
      1. Deep muscle layers adjacent to bone are most susceptible (as bone has higher resistance to electricity)
      2. High risk for amputation, especially upper extremities (28 to 45% risk)
      3. Early exploration and decompression in all suspected cases
  4. Mouth burns in young children who may have chewed on live wire
    1. May present with injury at lateral commissure at mouth
    2. Close interval follow-up with oral maxillofacial surgery or plastic surgery
    3. Complications
      1. Functional and disfiguring complications
      2. Delayed labial artery bleeding at 5-14 days after Burn Injury
  • Management
  • Disposition
  1. Burn center transfer indications
    1. High voltage extremity injury (esp. if concerns of Compartment Syndrome)
  2. Indications for admission with continuous cardiac monitoring (same criteria in children and adults)
    1. High Voltage Injury
      1. Admit all High Voltage Injury patients (and monitor with telemetry)
    2. Low Voltage Injury Observation Indications (may also observe on telemetry for 6 hours, and one ekg at discharge)
      1. Loss of consciousness
      2. Abnormal EKG (at any time in their evaluation following Electrical Injury)
      3. Extensive Soft Tissue Injury or intractable pain
  3. Indications for outpatient management (all criteria)
    1. Low-voltage exposure AND
    2. Normal exam AND
    3. Normal laboratory examination (No Myoglobinuria, normal CK, normal Renal Function) AND
    4. Electrocardiogram (EKG) normal
  • Complications
  • References
  1. Walrath, Wood, Della-Giustina (2019) Crit Dec Emerg Med 33(6): 3-11
  2. Martinez (2000) South Med J 93:1165-8 [PubMed]